Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Accurate Measurement of 3D and 2D Circular Centers With Application to LiDAR-Camera Extrinsic Calibration

arXiv:2511.06611v2 Announce Type: replace-cross Abstract: Accurate measurement of circular centers is a fun-damental geometric sensing problem in instrumentation and measurement tasks involving cameras, LiDARs, and other spa-tial sensors. In circular-target-based LiDAR-camera extrinsic calibration, a 3D circular center measured from LiDAR and its corresponding 2D projected center measured in the image serve as cross-modal geometric observations for estimating the rigid transformation between th

Published August 28, 2026 · Category: Robotics

Overview

arXiv:2511.06611v2 Announce Type: replace-cross Abstract: Accurate measurement of circular centers is a fun-damental geometric sensing problem in instrumentation and measurement tasks involving cameras, LiDARs, and other spa-tial sensors. In circular-target-based LiDAR-camera extrinsic calibration, a 3D circular center measured from LiDAR and its corresponding 2D projected center measured in the image serve as cross-modal geometric observations for estimating the rigid transformation between the two sensor frames. Conven-tional pipelines can bias both measurements: the 3D center is often obtained by sequential plane fitting, point projection, and 2D circle fitting, while the image ellipse center is frequently treated as the projected circle center even though the two generally differ under perspective projection. This paper focuses on accurate 3D and 2D circular-center measurement and uses LiDAR-camera extrinsic calibration as a representative applica-tion. A conformal-geometric-algebra estimator is integrated with RANSAC to jointly recover the 3D center, normal, and radius from noisy or partially observed LiDAR points. A chord-length-variance criterion then estimates the 2D projected center, with its twofold ambiguity resolved by homography validation or a quasi-RANSAC fallback. Synthetic and real-sensor experiments show that the proposed method improves circular-center measurement accuracy and reduces extrinsic calibration error across different target and sensor configurations.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →