Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework

arXiv:2609.12206v1 Announce Type: new Abstract: Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with comp

Published September 14, 2026 · Category: Robotics

Overview

arXiv:2609.12206v1 Announce Type: new Abstract: Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging the point cloud and RGB images of a structured light 3D camera, our proposed method performs an image-based segmentation for delineating the BPCs from the RGB images, accompanied by novel geometry-based thickness measurement algorithms performed on the point cloud scans. These algorithms combine the segmentation mask with the robot's forward kinematics data and a 3D point cloud scan to precisely measure the aforementioned metrics for complex-shaped BPCs. The proposed method was evaluated in simulation and experimental studies. In simulation studies, the algorithms were used to measure the thickness of some virtually created BPCs with known thickness. The comparison between the measured and true thicknesses demonstrates the high accuracy of the proposed method, achieving mean absolute errors between 0.025 mm and 0.057 mm in simulation at a spatial resolution of 0.1 mm x 0.1 mm per pixel. Furthermore, we successfully deployed the algorithms on our robotic bioprinting setup utilizing a structure light 3D camera, where complex patterns were printed and the developed methods utilized to accurately measure the thickness of printed BPCs.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →