Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Beyond Kinematics: Benchmarking Simulation Fidelity for Muscle-Driven Imitation Learning

arXiv:2609.21909v1 Announce Type: cross Abstract: In this work, we conduct a systematic comparison of two state-of-the-art motion-imitation reinforcement learning (MIRL) pipelines, one built on SCONE/HyFyDy and one built on MuJoCo/MyoSim. HyFyDy emphasizes physiological realism through detailed musculotendon modeling, while MuJoCo prioritizes computational efficiency and scalable policy learning. While recent work has demonstrated that both pipelines reproduce human kinematics with high fidelit

Published September 21, 2026 · Category: Robotics

Overview

arXiv:2609.21909v1 Announce Type: cross Abstract: In this work, we conduct a systematic comparison of two state-of-the-art motion-imitation reinforcement learning (MIRL) pipelines, one built on SCONE/HyFyDy and one built on MuJoCo/MyoSim. HyFyDy emphasizes physiological realism through detailed musculotendon modeling, while MuJoCo prioritizes computational efficiency and scalable policy learning. While recent work has demonstrated that both pipelines reproduce human kinematics with high fidelity, it remains unclear if they accurately capture the underlying neuromuscular behavior that produced the movement. This limitation is particularly important for robotic assistive-device design and control, where outcome measures such as muscle activation patterns and metabolic cost are often used as optimization targets. To conduct a systematic comparison, our work compares both pipelines using a common set of human motion-capture and electromyography (EMG) measurements. The results find that while both pipelines produce similar kinematics with relative accuracy, the muscle activations from HyFyDy are more aligned with the experimental EMG, as supported by the average pooled (RMSE, r) values for muscle activations from HyFyDy and MuJoCo: (0.164, 0.4) and (0.344, 0.11), respectively. While we conclude that the more advanced physiological realism of HyFyDy currently makes it more suitable for musculoskeletal modeling, both require further development to bring physiological realism to GPU-parallelizable simulation environments and advance robotic assistive device design.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →