Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception

arXiv:2608.13396v1 Announce Type: new Abstract: Shape and force sensing have long been critical bottlenecks in the development of compact capstan-driven continuum surgical robots, primarily due to the difficulty of obtaining cable tension information within the confined capstan assembly. To overcome these challenges, this paper presents an integrated design-modeling-sensing approach based on the concept of actuation-perception co-design. A compliant element is introduced into the motor mounting

Published August 14, 2026 · Category: Robotics

Overview

arXiv:2608.13396v1 Announce Type: new Abstract: Shape and force sensing have long been critical bottlenecks in the development of compact capstan-driven continuum surgical robots, primarily due to the difficulty of obtaining cable tension information within the confined capstan assembly. To overcome these challenges, this paper presents an integrated design-modeling-sensing approach based on the concept of actuation-perception co-design. A compliant element is introduced into the motor mounting bracket of the drive system, enabling micro-deformation under the cable reaction force and thereby allowing real-time cable tension measurement without occupying the compact capstan space. To address the modeling complexity arising from unconventional joint configurations introduced by the spatial cable routing strategy, a parallel computation framework based on a multibody short-thick-beam model is proposed, which captures shear effects in short beam segments and synergistic multi-cable interactions while achieving real-time performance. Building on this framework, stable shape and force sensing is achieved by incorporating a proximal multi-axis force/torque sensor as an additional measurement anchor. Following this design-modeling-sensing framework, capstan-driven continuum surgical robots with single- and dual-segment configurations are developed. Experimental results validate the proposed framework in both single- and dual-segment continuum robots, demonstrating real-time tip pose estimation together with contact force and location perception. By enabling cable tension feedback without compromising the compact capstan architecture, the proposed framework makes integrated perception feasible for capstan-driven continuum surgical robots.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →