Design and Evaluation of a Compliant Quasi Direct Drive End-effector for Safe Robotic Ultrasound Imaging

arXiv:2410.03086v2 Announce Type: replace Abstract: Robot-assisted ultrasound scanning promises to advance autonomous and accessible medical imaging. However, ensuring patient safety and compliant human-robot interaction during probe contact poses a significant challenge. Most existing systems either have high mechanical stiffness or trade performance for compliance. This paper presents a novel compliant end-effector designed to mount on robotic arms for safe and accurate robotic ultrasound ima

Published August 26, 2026 · Category: Robotics

Overview

arXiv:2410.03086v2 Announce Type: replace Abstract: Robot-assisted ultrasound scanning promises to advance autonomous and accessible medical imaging. However, ensuring patient safety and compliant human-robot interaction during probe contact poses a significant challenge. Most existing systems either have high mechanical stiffness or trade performance for compliance. This paper presents a novel compliant end-effector designed to mount on robotic arms for safe and accurate robotic ultrasound imaging, using a quasi-direct drive actuator to achieve passive mechanical compliance and precise active force control. To evaluate the end-effector's performance, we developed an ex vivo dynamic motion simulator platform for contact and scanning testing on tissue under simulated movements. The end-effector was evaluated against a UR3e robot arm using conventional force control strategies as a baseline. Single-point contact experiments from 2.5 N to 15 N show that the end-effector reduced force tracking RMS error by 80.1% on average. Trajectory scanning experiments at different speeds showed an average of 68.0% reduction in force tracking error. Statistically significant improvements were observed in four of six quantitative image quality and stability metrics using the end-effector. This work presents a novel approach for designing and evaluating compliant end-effectors, with the goal of improving safety and reliability in robotic ultrasound.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →