Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Diffusion-Based Body Schema Learning Enabling Abnormal-State Adaptation in Musculoskeletal Robots

arXiv:2608.01029v1 Announce Type: new Abstract: Musculoskeletal robots require an internal body schema that remains consistent under a wide range of physical state changes, including abnormalities such as muscle rupture and actuator jamming. Conventional approaches based on autoencoders or variational autoencoders learn average behaviors by projecting sensor and actuator signals into a low-dimensional latent space; however, exploration within the latent space alone has limited capability to han

Published August 4, 2026 · Category: Robotics

Overview

arXiv:2608.01029v1 Announce Type: new Abstract: Musculoskeletal robots require an internal body schema that remains consistent under a wide range of physical state changes, including abnormalities such as muscle rupture and actuator jamming. Conventional approaches based on autoencoders or variational autoencoders learn average behaviors by projecting sensor and actuator signals into a low-dimensional latent space; however, exploration within the latent space alone has limited capability to handle out-of-distribution or abnormal states that are not included in the training data. To address this limitation, this study proposes a diffusion-based framework for body schema learning in musculoskeletal robots. Unlike generative models that operate through low-dimensional latent spaces, diffusion models can directly and iteratively estimate physically consistent sensor and actuator values in the high-dimensional space through a denoising process, even under partial observations and constraints, without requiring retraining. By formulating body schema adaptation as a gradient-guided denoising process, the proposed method enables adaptive estimation of appropriate muscle lengths and muscle tensions even under abnormal conditions such as muscle rupture and actuator jamming. The validity of the proposed framework is verified through simulation experiments using a musculoskeletal robot model.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →