Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Digital Twin for Pre-Deployment Validation of AI-Driven Safety-Critical Industrial Edge Control Loops

arXiv:2610.11934v1 Announce Type: cross Abstract: Industrial environments are increasingly characterized by the tight interaction among physical processes, communication infrastructures, and intelligent applications. In this context, Digital Twins (DTs) have emerged as a key technology for system analysis and optimization. However, existing DT solutions typically focus either on industrial processes or communication networks, while lacking an integrated and application-aware perspective. To fil

Published October 9, 2026 · Category: Robotics

Overview

arXiv:2610.11934v1 Announce Type: cross Abstract: Industrial environments are increasingly characterized by the tight interaction among physical processes, communication infrastructures, and intelligent applications. In this context, Digital Twins (DTs) have emerged as a key technology for system analysis and optimization. However, existing DT solutions typically focus either on industrial processes or communication networks, while lacking an integrated and application-aware perspective. To fill this gap, this paper proposes a modular DT framework for industrial environments that jointly models physical processes, wireless communications, and application logic within a unified architecture. The feasibility of the proposed framework is experimentally validated through a real-world Proof-of-Concept (PoC) implemented in the BI-REX pilot line, involving a 5G-connected Autonomous Mobile Robot (AMR) transporting hazardous liquids and remotely controlled by an AI-driven application. The proposed DT is used to reproduce the behaviour of the real deployment and to investigate the impact of different placements of the AI application, including on-premise, edge, and remote cloud execution scenarios. Experimental results demonstrate a close agreement between DT predictions and PoC measurements in terms of both network-level metrics, such as Reference Signal Received Power (RSRP) and latency, and end- to-end application metrics, including application-level Round- Trip-Time (RTT). Moreover, the analysis shows how inaccuracies of network modeling can critically affect the feasibility of latency-sensitive industrial control loops, highlighting the potential of integrated DTs as tools for the pre-deployment design and validation of next-generation industrial systems.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from Industry →