Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Effects of Assistance Delay on Joint Mechanics and Energetics in Biological Torque Control of a Hip Exoskeleton

arXiv:2609.25417v1 Announce Type: new Abstract: Biological torque control directly maps an estimated human joint moment to exoskeleton assistance, providing a task-agnostic strategy for supporting diverse locomotor activities. However, it remains unclear whether a fixed state-to-torque mapping provides effective assistance across biomechanically distinct tasks. We examined how assistance delay affected hip exoskeleton performance during level-ground (LG), ramp-ascent (RA), and ramp-descent (RD)

Published September 23, 2026 · Category: Robotics

Overview

arXiv:2609.25417v1 Announce Type: new Abstract: Biological torque control directly maps an estimated human joint moment to exoskeleton assistance, providing a task-agnostic strategy for supporting diverse locomotor activities. However, it remains unclear whether a fixed state-to-torque mapping provides effective assistance across biomechanically distinct tasks. We examined how assistance delay affected hip exoskeleton performance during level-ground (LG), ramp-ascent (RA), and ramp-descent (RD) walking. Eight participants completed a zero-torque baseline condition and five active assistance conditions with delays ranging from 40 to 320 ms. Across tasks and active delays, assistance reduced net metabolic rate by 5.24%, positive biological hip joint work by 5.86%, and total lower-limb positive joint work by 1.68% (all p < 0.05). Assistance delay affected both joint-work outcomes (both p < 0.001) but not net metabolic rate. Mechanical unloading generally decreased with increasing delay, whereas metabolic benefits remained comparatively stable. Relative to the zero-torque condition, net metabolic rate decreased by 9.75% during LG and 7.20% during RA but increased by 1.23% during RD. We did not detect task-dependent differences in the delay response. Our findings indicate that biological torque mappings should be evaluated based on the target outcome and mechanical role of the assisted joint, and that predominantly positive-power assistance may not generalize to negative-work-dominant locomotion without modification.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →