Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Expanding the Workspace of Electromagnetic Navigation Systems Using Dynamic Feedback for Single- and Multi-agent Control

arXiv:2511.18486v2 Announce Type: replace Abstract: Electromagnetic navigation systems (eMNS) enable a number of magnetically guided surgical procedures. A challenge in magnetically manipulating surgical tools is that the effective workspace of an eMNS is often severely constrained by power and thermal limits. We show that system-level control design significantly expands this workspace by reducing the currents needed to achieve a desired motion. We identified five key system approaches that en

Published September 23, 2026 · Category: Robotics

Overview

arXiv:2511.18486v2 Announce Type: replace Abstract: Electromagnetic navigation systems (eMNS) enable a number of magnetically guided surgical procedures. A challenge in magnetically manipulating surgical tools is that the effective workspace of an eMNS is often severely constrained by power and thermal limits. We show that system-level control design significantly expands this workspace by reducing the currents needed to achieve a desired motion. We identified five key system approaches that enable this expansion: (i) motion-centric torque/force objectives, (ii) energy-optimal current allocation, (iii) real-time pose estimation, (iv) dynamic feedback, and (v) high-bandwidth eMNS components. As a result, we stabilize a 3D inverted pendulum on an eight-coil OctoMag eMNS with significantly lower currents (0.1-0.2 A vs. 8-14 A), by replacing a field-centric field-alignment strategy with a motion-centric torque/force-based approach. We generalize to multi-agent control by simultaneously stabilizing two inverted pendulums within a shared workspace, exploiting magnetic-field nonlinearity and coil redundancy for independent actuation. A structured analysis compares the electromagnetic workspaces of both paradigms and examines current-allocation strategies that map motion objectives to coil currents. Cross-platform evaluation of the clinically oriented Navion eMNS further demonstrates substantial workspace expansion by maintaining stable balancing at distances up to 50 cm from the coils. The results demonstrate that feedback is a practical path to scalable, efficient, and clinically relevant magnetic manipulation.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →