Finite-Data Safety Informativity Under Dynamic Asymmetric Actuation

arXiv:2610.01820v1 Announce Type: cross Abstract: When the system model is not fully known, measurement error and limited excitation can leave several models consistent with the same finite data. A command judged safe for one model may fail for another, while limited control authority can prevent the corrective action needed to preserve safety. To ensure safety under model uncertainty and asymmetric input limits, we develop a finite-data certificate that determines whether a command can enforce

Published October 2, 2026 · Category: Robotics

Overview

arXiv:2610.01820v1 Announce Type: cross Abstract: When the system model is not fully known, measurement error and limited excitation can leave several models consistent with the same finite data. A command judged safe for one model may fail for another, while limited control authority can prevent the corrective action needed to preserve safety. To ensure safety under model uncertainty and asymmetric input limits, we develop a finite-data certificate that determines whether a command can enforce a prescribed safety inequality. For a linearly parameterized safety channel with exactly known regressors and bounded aggregate residual error, we derive a support formula for the worst-case safety contribution of all data-consistent models. The formula identifies the regressor directions that admit a finite bound, allowing rank-deficient records to contribute to safety certification. Using certified componentwise bounds on actuator tracking error yields an affine inequality with a necessary and sufficient test for pointwise command feasibility. The affine inequality reduces computation of the closest certified command to a scalar root-finding problem. It also yields a closed-form gate that selects the largest certified fraction of a prescribed command segment. The proposed certificate guarantees output safety within its operating domain, provided the feedback is locally Lipschitz and the uncertainty bounds remain valid. Domain retention and full-state continuation extend this guarantee to all time. A vehicle study demonstrates that output safety can be certified from finite measurements in a safety-critical setting with model and actuator uncertainty.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →