Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

First Deployable Dynamic-CoM: A Unified Policy and Method-Agnostic Benchmark for Humanoid Single-Leg Balance

arXiv:2608.00500v1 Announce Type: new Abstract: Unified humanoid policies handle agile whole-body motion, yet stumble on a simple demand: staying balanced on one leg. On our single-leg-balance benchmark, eight released state-of-the-art general policies hold a clean single-leg stance on 0 of 90 test motions; they stay up only by stepping or hopping, recovering from imbalance rather than preventing it. Prevention needs the capture point (xCoM), the center of mass (CoM) extrapolated by its velocit

Published August 4, 2026 · Category: Robotics

Overview

arXiv:2608.00500v1 Announce Type: new Abstract: Unified humanoid policies handle agile whole-body motion, yet stumble on a simple demand: staying balanced on one leg. On our single-leg-balance benchmark, eight released state-of-the-art general policies hold a clean single-leg stance on 0 of 90 test motions; they stay up only by stepping or hopping, recovering from imbalance rather than preventing it. Prevention needs the capture point (xCoM), the center of mass (CoM) extrapolated by its velocity, which has never driven a hardware policy because it requires a base linear velocity no on-board sensor provides; expressed relative to the support foot, that velocity cancels exactly, leaving an observation reconstructible from encoders and IMU alone. We put this first deployable dynamic-CoM observation directly into the actor that runs on hardware, and pair it with a reward library translated term by term from human postural control, under one principle: prevention over repair. Trained by asymmetric FastSAC with a privileged critic and no distillation, the resulting policy, FDDC (First Deployable Dynamic-CoM), holds clean single-leg balance on 86 of 90 held-out motions across nine stratified pose classes and transfers to a real Unitree G1; in ablation, the dynamic-CoM observation is the single largest driver: removing it alone costs 40 points of clean single-leg balance. We release the full stack with the first method-agnostic, reproducible sim2sim benchmark for humanoid single-leg balance, scoring each policy in a simulator distinct from its training one, a step toward turning balance from a per-task trick into a capability the field can measure.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →