Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

GEGLU-Transformer for IMU-to-EMG Estimation with Few-Shot Adaptation

arXiv:2604.25670v2 Announce Type: replace Abstract: Reliable estimation of neuromuscular activation is a key enabler for adaptive and personalized control in wearable robotics. However, surface electromyography (EMG) remains difficult to deploy robustly outside laboratory settings due to electrode sensitivity, signal non-stationarity, and strong subject dependence. In this work, we propose an adaptive IMU-to-EMG learning framework that reconstructs continuous muscle activation envelopes from we

Published September 15, 2026 · Category: Robotics

Overview

arXiv:2604.25670v2 Announce Type: replace Abstract: Reliable estimation of neuromuscular activation is a key enabler for adaptive and personalized control in wearable robotics. However, surface electromyography (EMG) remains difficult to deploy robustly outside laboratory settings due to electrode sensitivity, signal non-stationarity, and strong subject dependence. In this work, we propose an adaptive IMU-to-EMG learning framework that reconstructs continuous muscle activation envelopes from wearable inertial measurements across heterogeneous movement conditions. The approach combines a Transformer encoder with Gaussian Error Gated Linear Units (GEGLU-Transformer) to enhance cross-subject generalization and enable rapid subject-specific personalization. Under a strict leave-one-subject-out (LOSO) protocol on a multi-condition lower-limb biomechanics dataset, the proposed architecture achieves r = 0.706 +/- 0.139 and R^2 = 0.474 +/- 0.208 without subject-specific adaptation. With only 0.5% adaptation data, performance increases to r = 0.761 +/- 0.030 and R^2 = 0.559 +/- 0.047, demonstrating rapid adaptation and early performance saturation. These results support attention-based architectures combined with lightweight adaptation as a practical and scalable alternative to direct EMG sensing for real-world wearable robotic applications.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →