Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Generative Semantic Scene Completion

arXiv:2608.26737v1 Announce Type: cross Abstract: Outdoor LiDAR semantic scene completion (SSC) recovers a dense semantic voxel grid from a scan observing 1% of the target volume, under class imbalance beyond 7,000x. We recast SSC as generative semantic scene completion (GSSC): a single discrete-diffusion formulation in three roles. First, paired sparse-dense scene synthesis (PS$^3$) generates matched sparse LiDAR observations with their dense semantic completions, addressing the long tail at i

Published August 28, 2026 · Category: Robotics

Overview

arXiv:2608.26737v1 Announce Type: cross Abstract: Outdoor LiDAR semantic scene completion (SSC) recovers a dense semantic voxel grid from a scan observing 1% of the target volume, under class imbalance beyond 7,000x. We recast SSC as generative semantic scene completion (GSSC): a single discrete-diffusion formulation in three roles. First, paired sparse-dense scene synthesis (PS$^3$) generates matched sparse LiDAR observations with their dense semantic completions, addressing the long tail at its source and yielding the PS$^3$-SemanticKITTI corpus we train on alongside SemanticKITTI. Second, semantic-guided generative scene completion (SGSC) generates the scene from noise with multinomial discrete diffusion, conditioned on the sparse scan through a bird's-eye-view semantic map and a sparse 3D feature stream. Third, the same framework instead refines an existing completion in one flow-matching step: structured source discrete diffusion (S$^2$D$^2$). S$^2$D$^2$ improves the mIoU of SGSC's own output and every external SSC base tested, without base retraining or test-time adaptation. On the strongest base, one step without test-time augmentation reaches 38.8% mIoU on the SemanticKITTI hidden test. To our knowledge that is the best causal, single-sweep, single-sample result on that leaderboard, +2.1 pp over the previous best published score under the same restriction. Four correction steps with eight-view test-time augmentation reach 39.2%, outside that restriction.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →