Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

H-PAC Hand: Control-Oriented Modeling and Tendon-Elasticity Compensation for an Underactuated Robotic Hand

arXiv:2608.16712v1 Announce Type: new Abstract: Underactuated tendon-driven hands offer compact actuation and passive compliance, but tendon elongation under restoring-spring loading introduces configuration-dependent joint deviations. This paper presents H-PAC, a modular 6-actuator, 15-DoF robotic hand with a control-oriented modeling and implementation framework. A sparse analytical actuator-joint model is derived from the tendon-routing geometry, and a mechanics-based compensation model is d

Published August 18, 2026 · Category: Robotics

Overview

arXiv:2608.16712v1 Announce Type: new Abstract: Underactuated tendon-driven hands offer compact actuation and passive compliance, but tendon elongation under restoring-spring loading introduces configuration-dependent joint deviations. This paper presents H-PAC, a modular 6-actuator, 15-DoF robotic hand with a control-oriented modeling and implementation framework. A sparse analytical actuator-joint model is derived from the tendon-routing geometry, and a mechanics-based compensation model is developed to account for tendon-elasticity-induced joint errors. The proposed method is implemented in a hierarchical architecture: a host computer performs workspace-constrained posture mapping and compensation, while an ESP32 generates synchronized commands for six position-controlled servos. The same control parameters and execution strategy are used across all tasks without task-specific retuning. Monotonic servo-sweep experiments show that the compensation substantially improves joint-angle prediction. The MAE of the index DIP joint decreases from 1.15 degrees to 0.18 degrees, and all nine evaluated joints achieve an MAE below 0.23 degrees. Representative postures and grasping configurations are further executed using the same control pipeline without external joint or force sensing in the control loop. The results demonstrate a practical approach to improving posture reproducibility in compact underactuated robotic end-effectors.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →