Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Human-Inspired Framework for Robotic Craniotomy: Integrating Multimodal Fusion and Adaptive Trajectory Adjustment

arXiv:2607.21058v1 Announce Type: new Abstract: Manual craniotomy is a high-risk, skill-dependent procedure associated with surgeon fatigue and potential dural injury. While robotic approaches have improved safety, existing open-loop systems rely solely on preoperative images and cannot compensate for intraoperative registration errors or tissue deformation. To address this, we propose a human-inspired closed-loop robotic craniotomy framework that intelligently integrates preoperative planning

Published July 24, 2026 · Category: Robotics

Overview

arXiv:2607.21058v1 Announce Type: new Abstract: Manual craniotomy is a high-risk, skill-dependent procedure associated with surgeon fatigue and potential dural injury. While robotic approaches have improved safety, existing open-loop systems rely solely on preoperative images and cannot compensate for intraoperative registration errors or tissue deformation. To address this, we propose a human-inspired closed-loop robotic craniotomy framework that intelligently integrates preoperative planning with intraoperative execution. An adaptive dual-contour fusion algorithm is employed to generate trajectories that conform to complex cranial geometries while maintaining a consistent tool-bone relative pose. For intraoperative perception, a multimodal two-stage cross-modal attention block (CMA)-temporal convolutional network (TCN)-Transformer network combined with an adaptive Bayesian filter fuses force and acoustic signals to achieve robust breakthrough detection under varying bone conditions. Upon detection, an in-situ projection-based trajectory adjustment strategy dynamically compensates for depth deviations, enabling safe residual bone isolation. Experiments on bovine ribs show a breakthrough prediction accuracy of 97%, a detection latency of 0.048 +/- 0.097 s, and a maximum overshoot of 0.29 mm. All four ex vivo cranial experiments were successfully completed without dural injury. These results demonstrate that the proposed cybernetic framework enables safe and autonomous craniotomy with highly effective closed-loop control.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →