Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Impedance MPC with Disturbance Estimation for Dexterous Hand Control

arXiv:2606.14606v1 Announce Type: new Abstract: Dexterous hands must simultaneously track precise finger trajectories and maintain safe, compliant contact -- objectives in tension for any fixed-gain controller. We present an actuator-agnostic Impedance Model Predictive Control (Impedance MPC) framework for dexterous fingers, instantiating the constant-$A_d$ offset-free architecture established for physical human-robot interaction (pHRI); its stability, recursive-feasibility, and input-to-state-

Published June 15, 2026 · Category: Robotics

Overview

arXiv:2606.14606v1 Announce Type: new Abstract: Dexterous hands must simultaneously track precise finger trajectories and maintain safe, compliant contact -- objectives in tension for any fixed-gain controller. We present an actuator-agnostic Impedance Model Predictive Control (Impedance MPC) framework for dexterous fingers, instantiating the constant-$A_d$ offset-free architecture established for physical human-robot interaction (pHRI); its stability, recursive-feasibility, and input-to-state-stability guarantees are inherited by preserving the architectural assumptions. An algebraic feedforward reduces the tendon transmission -- hydraulic, cable, pneumatic, twisted-string, or series-elastic -- to a constant-coefficient double integrator, so the QP cost inverse is precomputed offline and a 10-step receding-horizon quadratic program runs at 500\,Hz while enforcing hard constraints on contact force (ISO/TS 15066), actuation limits, and jerk. An encoder-only augmented-Kalman disturbance state drives steady-state error to zero under any constant contact load. On a hydraulically actuated finger -- the worked example platform, adding pressure and cavitation constraints -- the 500\,Hz Kalman MPC attains 0.5\,mrad RMS, 0.1\,mrad steady-state, and 6.6\,mrad peak deflection under 1.5\,Nm contact: 183$\times$, 1500$\times$, and 23$\times$ better than classical impedance. The realized first-move stiffness (18$\to$323\,Nm/rad with update rate) is independently verified. The architecture scales to a 16-DOF LEAP Hand MuJoCo simulation, recovering from 2.5\,N grasp-load disturbances within 0.7\,s.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →