Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

LabRobFail: A Benchmark for Robotic Failure Analysis in Chemical Self-driving Laboratories

arXiv:2607.23704v1 Announce Type: new Abstract: The deployment of embodied agents in self-driving laboratories could accelerate scientific discovery, yet their reliability is constrained by the irreversible and safety-critical nature of chemical experiments. Progress is further hindered by scarce failure data and the lack of fine-grained evaluation protocols. To address these challenges, we introduce LabRobFail, a failure-centric framework for learning and evaluating robotic failure analysis in

Published July 28, 2026 · Category: Robotics

Overview

arXiv:2607.23704v1 Announce Type: new Abstract: The deployment of embodied agents in self-driving laboratories could accelerate scientific discovery, yet their reliability is constrained by the irreversible and safety-critical nature of chemical experiments. Progress is further hindered by scarce failure data and the lack of fine-grained evaluation protocols. To address these challenges, we introduce LabRobFail, a failure-centric framework for learning and evaluating robotic failure analysis in chemical laboratories. LabRobFail-Sim injects controllable failures at the control, physics, and semantic levels, enabling the construction of LabRobFail-Data, which contains over 20,000 trajectories across 70+ task scenarios, five failure categories, and 11 fine-grained failure types. LabRobFail-Bench evaluates six capabilities spanning task understanding, failure detection, temporal localization, severity assessment, failure classification, and actionable correction. We further develop LabRobFail-VLM, a domain-specialized vision-language model that generates structured failure diagnoses and recovery instructions. On seen environments, it achieves 92.58% failure-detection accuracy and 85.58% temporal-localization accuracy, substantially outperforming general-purpose VLMs. When integrated as a real-time supervisor, it improves downstream VLA task success rates by 10-20 percentage points, demonstrating the value of fine-grained failure understanding for closed-loop recovery and reliable laboratory autonomy. Our code and data are available at https://github.com/Su-ISE-2001/SciRobo

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →