Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

MarUco: A Markerless 6D Pose Estimation Framework for Closed-Loop Control of Surgical Continuum Manipulators

arXiv:2602.16365v2 Announce Type: replace Abstract: Flexible endoscopic continuum manipulators offer high dexterity and access to complex anatomy, but nonlinear hysteresis limits feedforward control accuracy. Closed-loop control can compensate for these errors but requires accurate six-degree-of-freedom (6D) end-effector pose feedback. We present MarUco, a markerless 6D pose estimation framework for closed-loop control using only stereo vision during operation. A photorealistic pseudo-rigid-bod

Published September 2, 2026 · Category: Robotics

Overview

arXiv:2602.16365v2 Announce Type: replace Abstract: Flexible endoscopic continuum manipulators offer high dexterity and access to complex anatomy, but nonlinear hysteresis limits feedforward control accuracy. Closed-loop control can compensate for these errors but requires accurate six-degree-of-freedom (6D) end-effector pose feedback. We present MarUco, a markerless 6D pose estimation framework for closed-loop control using only stereo vision during operation. A photorealistic pseudo-rigid-body simulation pipeline generates large-scale annotated training data without manual labeling. A multifeature fusion network integrates masks, keypoints, heatmaps, and bounding boxes from both stereo views to estimate an initial pose, followed by a learned single-pass render-and-compare module that refines the pose without iterative optimization. Kinematics-free hand-eye calibration estimates camera-to-robot-base extrinsics, and self-supervised adaptation uses unlabeled real stereo pairs to mitigate sim-to-real pose error. Across 1,000 real samples, MarUco achieves translation and rotation errors of 0.78 $\pm$ 0.50 mm and 3.07 $\pm$ 1.25{\deg}, respectively, with a total processing time of 52.4 ms per stereo pair. In closed-loop experiments over eight reference paths, MarUco achieves a mean terminal translation error of 1.8 mm, an 88% reduction relative to uncompensated open-loop control. To the best of our knowledge, this is the first markerless position-based visual servoing framework for continuum manipulators.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →