Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Surgical Kinematics from Monocular Video with Learned Articulated Motion Constraints

arXiv:2609.27227v1 Announce Type: cross Abstract: Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument position, orientation and jaw angle from monocular video. Our visual representation combines global attention pooling of frozen DINOv3 features with local pooling at instrument landmarks from fine-tuned SAM 3.1 masks. Our shared Transformer encoder

Published September 24, 2026 · Category: Robotics

Overview

arXiv:2609.27227v1 Announce Type: cross Abstract: Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument position, orientation and jaw angle from monocular video. Our visual representation combines global attention pooling of frozen DINOv3 features with local pooling at instrument landmarks from fine-tuned SAM 3.1 masks. Our shared Transformer encoder and temporal convolutional heads integrate this representation with mask geometry, monocular depth and visual state estimates from arm-specific multilayer regression networks. Our position branch predicts displacement magnitude and direction separately to preserve traveled distance. We fit trajectories to predicted state observations and motion increments by differentiable weighted least squares, expressing quaternion observations relative to cumulative predicted rotations to obtain a quadratic orientation objective. We evaluate reconstruction across 2,802 Open-H episodes. Compared with LiveMAE on the main Open-H benchmark, our method reduces path-length mean absolute error from 0.45 to 0.34\,cm and increases temporal mean average precision for motion segmentation from 44.54\% to 54.44\%.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →