TiBCLaG: Hybrid design approach for a trigger-induced bistable compliant laparoscopic grasper

arXiv:2603.18559v2 Announce Type: replace Abstract: Industrial laparoscopic graspers rely on multi-link rigid mechanisms manufactured to tight tolerances, resulting in high manufacturing and assembly costs. This work presents the design and proof-of-concept validation of a monolithic, fully compliant, bistable, laparoscopic grasper that eliminates the need for multiple rigid links, thereby reducing part count. The device integrates a compliant trigger and a compliant gripper end-effector, coupl

Published July 22, 2026 · Category: Robotics

Overview

arXiv:2603.18559v2 Announce Type: replace Abstract: Industrial laparoscopic graspers rely on multi-link rigid mechanisms manufactured to tight tolerances, resulting in high manufacturing and assembly costs. This work presents the design and proof-of-concept validation of a monolithic, fully compliant, bistable, laparoscopic grasper that eliminates the need for multiple rigid links, thereby reducing part count. The device integrates a compliant trigger and a compliant gripper end-effector, coupled via a control push-rod, to achieve stable grasping without continuous user input. A hybrid approach combining an analytical model, iterative prototyping, and finite element analyses is employed to design the laparoscopic grasper. The trigger mechanism is synthesized using a Two-Element Beam Constraint Model as a design framework to control the deformation and stiffness of I-beam-like elements. This technique enables elastic energy storage while preventing snap-through instability. The end-effector is designed as a compliant gripper to achieve adaptive grasping through elastic deformation. The laparoscopic design presented here is fabricated using fused deposition 3D printing. A comparative study of the jaws' opening and closing performance is presented using nonlinear finite element analysis and experimentation. The fabricated prototype demonstrates reliable bistable actuation, confirming the feasibility of such compliant laparoscopic grasper architectures.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →