Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

arXiv:2609.14984v1 Announce Type: new Abstract: This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model

Published September 15, 2026 · Category: Robotics

Overview

arXiv:2609.14984v1 Announce Type: new Abstract: This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from Research →