Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Colon3R: Cross-Domain 3D Reconstruction from Monocular Colonoscopic Video

arXiv:2609.23961v1 Announce Type: cross Abstract: Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue motion. Conventional multi-view 3D reconstruction methods rely on stable correspondences and approximate rigidity, which are often violated in colonoscopy. Existing endoscopic methods often rely on domain-specific supervision, whereas there are not en

Published September 22, 2026 · Category: Robotics

Overview

arXiv:2609.23961v1 Announce Type: cross Abstract: Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue motion. Conventional multi-view 3D reconstruction methods rely on stable correspondences and approximate rigidity, which are often violated in colonoscopy. Existing endoscopic methods often rely on domain-specific supervision, whereas there are not enough in-vivo labeled data available to adapt geometry foundation models to clinical colonoscopy. We present Colon3R, a cross-domain semi-supervised framework built on pretrained VGGT that transfers coupled camera, depth, and pointmap geometry from labeled phantom and simulated data to unlabeled in-vivo colonoscopy without requiring target-domain geometric annotations. Unlike source-only fine-tuning, which learns only from phantom and simulated data, Colon3R directly exploits unlabeled in-vivo video through teacher-derived cross-view supervision. Our proposed hierarchical quasi-rigid reliability selects reliable supervision at the sequence, directed-pair, and pixel levels, while source-preserving adaptation retains the learned coupled geometry during target-domain adaptation. Extensive experiments demonstrate that our method achieves superior overall performance over state-of-the-art approaches in depth, pointmap, and camera pose estimation. Qualitative comparisons on real in-vivo colonoscopy further show substantially more complete and geometrically consistent reconstructions than competing methods under clinical domain shift. The code will be public available after the paper is accepted.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →