Industry Monitor Humanoid Industrial & Cobot AGV / AMR Quadruped Reducers · Servos · Sensors Drones & Autonomy Embodied AI
Robos News
Robotics

Subject-Specific Predictive Musculoskeletal Simulations of Lower-Limb Exoskeleton Assistance: Metabolic and Biomechanical Effects of Joint Assistance Strategies

arXiv:2610.02991v1 Announce Type: new Abstract: Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-b

Published October 5, 2026 · Category: Robotics

Overview

arXiv:2610.02991v1 Announce Type: new Abstract: Lower-limb exoskeletons have made considerable progress in reducing energy expenditure during walking. However, designing optimal assistance strategies remains challenging, particularly given inter-individual variability in anthropometry and biomechanics. This study explores energy-optimal lower-limb joint-assistance strategies using predictive simulations with musculoskeletal models. Subject-specific models of six able-bodied subjects, with BMI-based muscle strength scaling, were used in predictive simulations to generate gait at self-selected walking speeds. Ideal actuators were incorporated to simulate various combinations of joint assistance at peak levels of 25 Nm and 50 Nm to examine the effects of assistance on gait and metabolic savings. The effects of each assistance configuration were assessed through cost of transport (COT), joint kinematics, muscle activations, assistive torques, and joint-level power metrics to characterize the biomechanical and energetic impacts of different assistance strategies. At 50 Nm, combined H+K+A (hip-knee-ankle) assistance resulted in the greatest mean COT reduction of 48.50 +/- 4.55%, with individual reductions ranging from 42.22% to 54.65% across the subjects. Among single-joint conditions, assisting the hip was most effective, reducing COT by 31.77 +/- 5.21%; the knee and ankle produced smaller, comparable reductions (19.17% and 17.02%). H+A (hip-ankle) assistance (44.60 +/- 7.08%) emerged as the most effective two-joint assistive configuration. Increasing the torque bound increased positive assistive power primarily at the hip and ankle, while knee assistance showed little sensitivity and delivered positive power near pre-swing. These results support H+A assistance as an efficient two-actuator target, while identifying the knee's atypical pre-swing power strategy as a candidate for targeted experimental validation.

Source

Originally published at arxiv.org.

Related Articles

Robos News Newsroom

Robos News reports on robotics research, components, manufacturers, field deployments, and industrial automation worldwide. Tip our newsroom: [email protected]

Email the newsroom →
Reporting standard: Product specifications, deployment counts, and performance claims are attributed to their source. Safety-critical decisions should be based on the applicable technical documentation and validation for the operating environment.
More from News →